Voici notre produit

Pressure Drop Online Calculator Strainers and grids / Conical strainer. Diameter of pipe D:: Flow medium: Flow medium: Condition: liquid gaseous: Volume flow: Weight density: Dynamic viscosity: Additional data for gases: Pressure (inlet, abs): Temperature (inlet):


Sample Sure Flow basket strainer calculation Estimate pressure drop across 100 mesh lined Sure Flow Y-strainer provided in a 10″ line with following data. • Flow rate = 1,300 GPM • Viscosity = 100 cP • Specific Gravity = 0.80 • 100 mesh screen The Pressure Drop Chart for Y-strainer indicates a drop


Pressure Drop Online-Calculator Calculation of pressure drops of flowing liquids and gases in pipes and pipe elements (laminar and turbulent flow). Note: Calculations are possible only, if Javascript is activated in your browser. Pressure Drop Online-Calculator for small mobiles. This version is usable for browsers without Javascript also.


25-4-2006· His answer was 2 to 3psid clean pressure drop for the normal flow condition. FYI, the specs I wrote were 276000pph, MW=30, 920F, 45psig, 0.03cP. I called for 0.2psid clean, and 1psid dirty (30% or more plugged), but the available length of piping we allowed was apparently too short for a design meeting my specs.


Sample calculation: Estimate pressure drop across 100 mesh lined Basket Type strainer provided in a 6″ line with following data. Flow rate = 700GPM Viscosity = 100cP Specific Gravity = 1 The Pressure Drop Chart for Basket strainers indicates a drop of 0.9psi. The Screen openings chart indicates the % open area of 100 mesh is 30%. From chart



22-12-2005· I'm am looking for typical pressure drops across DN 750 (30") and DN 600(24") conical strainers on a cooling water application. Flow rate is approx 2400m3/h (~10,000gpm). The strainers are fabricated from 3mm (1/8") perforated plate and the open area is 150% of line cross sectional area. Local supplier cannot help with data.


How to Use: 1) Determine the pressure drop (P1) through the strainer with water flow and standard screens. 2) If non-standard screens (i.e. 40 mesh, etc.) are being used, apply factors in Chart #1 to determine corrected pressure drop (P2). 3) Multiply P1 or P2 (if used) by the specific gravity of the fluid actually flowing through the strainer to get P3. 4) Using Chart #2 multiply P3 by the


PRESSURE DROPS IN CONICAL FLOW OF MOLTEN METAL Edward W ALICKI, Anna W ALICKA Depmtment ofMechanics, Technical University of Zielona Góra 65-016 Zielona Góra, ul. Szafrana 2, POLAND ABSTRACI Practtcal mouldmg processes mvolve geometrieaBy complex d1es .


PRESSURE DROP CHART Temporary Cone and Basket Strainers (TC, TB) KECKLEY This pressure drop chart is based on the flow of clean water through the Keckley Strainer Styles listed above with screen perforations ranging from 1/16” through 1/8”. TO USE CHARTS: Find your desired rate of flow (GPM) on the left hand side of the chart.


→ Free File Repository Download Pressure Drop Calculator for Strainers 1 3 Votes strainer pressure drop calculator basket tee. 5. Well documented pressure loss calculator for use with basket and tee style strainers. Disclaimer: All


Pressure Drop Online Calculator for Mobile and PDAElement of pipe: Strainers and grids / Conical strainer Get Price free of pressure drop calculation for conical strainer for . calculator for pressure in conical strainer SF Pressure Drop for Windows calculates pressure drops of flowing liquids and gases in pipes ystrainer, screen basket filter, conical strainer Pressure drop check for liquid


BULLETIN STR995-1 PRESSURE DROP DATA BASKET STRAINERS THREADED BASKET STRAINER PRESSURE DROP LIQUIDS (Sizes 1/2" to 2") FIGURE 1 FLANGED BASKET STRAINER PRESSURE DROP LIQUIDS (Sizes 2" to 24") FIGURE 2 Notes: Pressure drop curves are based on water flow with standard screens See next page for correction factors to be used with other


of strainer. In addition, operating pressure drops are normally higher and maximum allowable pressure drops lower than with other types of strainers. Figure 11 . For applications where continuous operation is required, a scraper strainer provides removal of solids without interrupting flow (Fig. 12). Disassembly of the strainer is not required for


influence pressure drop of flow through the strainer. As a general rule of thumb, a pressure of greater than 2 PSI through a clean strainer usually indicates the strainer selected is too small for the intended application. In some cases, the strainer size may not always be the same size as the pipe diameter.


This is a sample of the Strainer pressure drop calculator. To access the working calculator, please sign up for free membership trial. This application can be used to estimate the pressure drop across a strainer with a standard mesh for given strainer size and liquid flow. Strainer size: inches: Liquid volumetric flowrate: m 3 /hr: Liquid


Temporary Strainer Drawings and Pressure Drop Chart You can use the differential pressure chart to estimate the approximate clean pressure drop across a temporary cone or basket style strainer. The chart data is based upon water and perforations ranging from 1/8" to 1/16".


Contact Information: Software-Factory Norbert Schmitz Am Moenchhof 7a 67105 Schifferstadt Germany Tel. +49 6235 / 92 20 14 Fax +49 6235 / 95 20 15 E-Mail: [email protected]


You can't use this calculator for compressible gas flow where the pressure of the gas is changing more than 5-10%. For that purpose, you can use one of available gas pressure drop calculators. You can't use this calculator if the fluid is non-Newtonian,i.e., its viscosity is changing with the shear rate or due to some other changed condition.


Titan Flow Control, Inc. also offers downloadable Pressure Drop Charts for your convenience. Click on the images to the right to download the Adobe PDF sheets for Titan FCI's Strainer and Check Valve models. For additional help determining the pressure drop for a Titan Flow


Engineering Specification for the Selection, Installation and Maintenance of Pipeline Strainers Prepared by used in a right angle flow application (Fig. 3). because of the more circuitous path the liquid must take through a duplex strainer, pressure drop is higher than through the equivalent size single or twin basket strainer.


As most strainer screens have very large straining and free areas, the pressure drop across the strainer is very low when used on steam or gas systems (see Example 12.4.1). However, in pumped water or viscous fluid systems, the pressure drop can be significant. Strainers should have flow capacities quoted in terms of a capacity index or Kvs value.


SF Pressure Drop 7.x for Windows calculates pressure drops of flowing liquids and gases in pipes y-strainer, screen basket filter, conical strainer Pressure drop check for liquid or gas applications. 2.2 Pressure Drop Check for Liquid or Gas Applications. Note: These online calculators are for your convenience. Cone Strainers.


Y-Strainer Flow Rate Vs Pressure Drop “Y” Strainers take their name from their configuration. They are most commonly used in pressurized lines, gas or liquid, but


Online calculator to quickly determine Pressure Loss through Piping for Gas. Includes 53 different calculations. Equations displayed for easy reference.


Temporary conical strainers are to be placed with the cone pointing opposite to the direction of flow. 9. Pressure Drop across a Strainer / Mesh Number. Basket type strainers shall have a minimum free flow area of 1.5 times the cross Before commencing on preparation of strainer specification the first step involves identifying the


Tel. 905-335-8777 Fax. 905-335-0977 Toll Free Tel. 1-866-872-0072 Toll Free Fax. 1-866-872-0073 14 Engineering Data Screen Openings for Basket Strainers Purpose If the basket strainer is being used for protection rather than direct filtration,IFC’s standard screens will suffice in most applications. Service


Comparing different type of strainers, tee-type and conical-type strainers have higher pressure drop values compared to Y-type and basket-type strainers. Capacity or flow open area of a strainer affects the operation characteristics of the strainer in terms of how long the strainer can operate without cleaning and creating a pressure loss.


STRPDC-0816 TECHNICAL AND PERFORMANCE DATA PRESSURE DROP CHARTS f WYE & BASKET STRAINERS TITAN TITAN FLOW CONTROL, INC. Tel: 910-735-0000 s Fax: 910-738-3848 s [email protected] titanfci 290 Corporate Drive s PO Box 7408 s Lumberton, NC 28358 TITAN FLOW CONTROL, INC.